| Item details | |
| Item description | G_02332 | |
 |
| Description | Triax - PE - 50 Ohm |
| Item number | 22510117 |
| 2002/95/EC (RoHS) | compliant |
| Data sheet |
|
| Phase | Production | | | |
 |
| Cable design | Jump to [Top] |
|
| | Material | Detail | Diameter |
| Centre conductor | Copper | Strand | 0.49 | mm |
| Dielectric | PE | | 1.5 | mm |
| Outer conductor | Copper | Braid - 96% coverage | 2 | mm |
| Jacket | PVC | RAL 7035 - gr | 2.55 | mm |
| Tolerance of jacket | | | ± 0.13 | mm |
 |
| Electrical data | Jump to [Top] |
| Operating Frequency | | ≤ 2 | GHz |
| Nom. attenuation | Values and graph see below | Coefficient a | 0.817 | |
| | | Coefficient b | 0.1489 | |
| CW Power | Values and graph see below | | | |
| Impedance | | 50 ± 2 | Ω |
| Capacitance | | 100.7 | pF/m |
| Propagation Velocity | | 66 | %of c |
| Signal Delay | | 5.03 | ns/m |
| Insulation Resist | | >100000000 | MΩm |
| Test Voltage | | 3 | kVrms |
| Operating Voltage | at sea level | 1.5 | kVrms |
| Inner Cond Res DC | typical | | 126.2 | Ω/km |
| Outer Cond R. DC | typical | | 31.6 | Ω/km |
 |
| General data | Jump to [Top] |
| Operating Temp min | | | -40 | °C |
| Operating Temp max | | | 85 | °C |
| Installation Temp min | | | -20 | °C |
| Installation Temp min | | | 60 | °C |
| Weight | | 3 | kg/100m |
| Static Bend Radius | | | 20 | mm |
| Repeated Bend Radius | | | 42 | mm |
 |
| Suitable connectors, grounding kits and installation material | Jump to [Top] |
| Cable groups | For details refer to the online coaxial connector catalogue or contact your nearest HUBER+SUHNER representative | Cable Group 2
| W1
| |
 |
| Nominal attenuation and power | Jump to [Top] |
 |  |  |  |  | | Frequency | Attenuation* | Power** | Attenuation and power graph | | [GHz] | [dB/m] | [dB/ft] | [W] | | | 0.01 | 0.08 | 0.03 | 380 | | 0.05 | 0.19 | 0.06 | 170 | | 0.10 | 0.27 | 0.08 | 120 | | 0.15 | 0.34 | 0.10 | 98 | | 0.20 | 0.40 | 0.12 | 85 | | 0.30 | 0.49 | 0.15 | 69 | | 0.40 | 0.58 | 0.18 | 60 | | 0.45 | 0.62 | 0.19 | 57 | | 0.50 | 0.65 | 0.20 | 54 | | 0.60 | 0.72 | 0.22 | 49 | | 0.80 | 0.85 | 0.26 | 42 | | 0.85 | 0.88 | 0.27 | 41 | | 0.90 | 0.91 | 0.28 | 40 | | 0.95 | 0.94 | 0.29 | 39 | | 1.00 | 0.97 | 0.29 | 38 | | 1.80 | 1.36 | 0.42 | 28 | | 1.90 | 1.41 | 0.43 | 28 | | 2.00 | 1.45 | 0.44 | 27 | | | | |
|
 |
| Please note: | Attenuation values at +25°C ambient temperature and sea level * Power values at +40°C ambient temperature and sea level ** |
| Required plug-in: | To see the 'Attenuation and power graph' the Adobe SVG Viewer version 3.0 or higher must be installed. |
 |
| Tests | Jump to [Top] |
| Following tests have been passed successfully. For any details please contact your nearest HUBER+SUHNER representative. |
| Test description | Specification / Paragraph / Method |